Leakage tester lindab | smart tools LTEST Description and advantages Complete equipment for field measuring of leakage in duct systems, e.g. for handing over measuring according to EN 12599. Also for serial testing of production or in laboratories directly connected via USB. Measures leakage, leakage factor and achieved tightness class according to EN 13779. Suitable for measurements according to the standards EN 1507 and EN 12237 plus EN 1751 and EN 15727. Large working range, for big systems as well as single fit- tings and residental ventilation systems. Simple handling and automatic measuring cycle. Operate with detailed user guide or in expert mode. Printing of measuring protocol on site with termo printer. Permanent data storage possible. Customer and measure data management via supplied PC program. Handy set, main device in plastic trunk, accessories in alu- minium trunk, easy to transport and store. Available special accessories and articles of consumption Set of filter pads LTFP, 5 pcs. Plastic hose LTLMS (Ø 50 mm length 10 m) with female con- nection Ø 100 Set of printer paper LTPP, for TD 100, 10 rolls Seal-off bladder LBLADD, size 3 for Ø 100–250 mm Seal-off bladder LBLADD, size 5 for Ø 200–400 mm Seal-off bladder LBLADD, size 10 for Ø 315–630 mm Ordering example Product Type LTEST 600 Delivery includes Leakage meter LTEST 600 Adapter type 0,3 Adapter type 3,0 Connection cable, 230 V, 10 A (length 2,5 m) Termo printer TD 100 incl. 4 batteries 1,5 V AAA Set of printer paper LTPP, for TD 100, 10 rolls Plastic hose LTLMS (Ø 50 mm, length 3,75 m) with female connection Ø 100 Rubber hose (Ø 10 mm, length 10 m) with female connec- tion Ø 100 Hose for adapter 0,3 (length 4 m) Brass nipples, 2 pcs. Set of filter pads LTFP, 5 pcs. Seal-off set, for circular, consisting of Seal-off bladder LBLADD (size 3), 5 pcs. Seal-off bladder LBLADD (size 5), 5 pcs. Seal-off bladder LBLADD (size 10), 5 pcs. Hand air pump USB-cable User manual Calibration protocol Download software from www.lindab.com Technical data Pressure measurement Principle piezo-resistive semi-conductor sensor Measuring range -7000 to +7000 Pa Resolution 0,1 Pa to ±900 Pa, above 1 Pa Accuracy the highest of ±0,5 Pa or ±2,5 % of reading Flow measurement (at 1013 hPa and 20 °C) Principle hot film anemometer Measuring range 0,0000 to 55,00 l/s (230 V, 50 Hz) 0,0000 to 40,00 l/s (110 V, 60 Hz) Resolution 0,0001 l/s up to 0,3000 l/s, 0,001 l/s up to 3,000 l/s, 0,01 l/s above Accuracy the highest of ±0,0009 l/s or ±5 % of reading Measuring range for the adapters Adapter 0,3 0,00 to 0,3000 l/s Adapter 3,0 0,300 to 3,000 l/s Without adapter 3,01 to 55,00 l/s General data Power supply Power consumption Working temperature Storage temperature Main device weight Total weight 230 V, 50 Hz 110 V, 60 Hz max. 9 A +5 to +40 °C -20 to +50 °C approx. 9,5 kg approx. 25 kg We reserve the right to make changes without prior notice 1 2020-02-10
Download PDF file