Page number 2
lindab | we simplify construction Control equipment Content Page Overview. 3 Order code. 3 Display handling and indications. 4 Parameter menu. 5 Connection descriptions. 5 Technical data Regula Combi. 6 Regula Control Pascal. 7 Regula Connect Pascal. 7 Regula Connect Basic/Multi. 8 Accessories. 9 Regula Combi 1.5 2 Lindab reserves the right to make changes without prior notice 2021-04-27
Page number 3
Control equipment Overview Use Customized control equipment for water and airborne cli- mate systems with individual regulation. Regula Combi can control heating and cooling in sequence, VAV in combination with heating and cooling, Change-Over systems, as well as communicate with Modbus/EXOline/ Bacnet Master systems. Regula Connect Pascal, Regula Connect Multi, Regula Connect Basic and Regula Control Pascal are connection cards for the flexible connection of air and waterborne sys- tems. For further informations on the Regula connect Pascal, please see the Lindab Pascal documents. Regula Combi is available for installation on the wall. Regula Combi can be integrated in a chilled beam directly also. The Regula Connect cards are integrated in or on our products. Worth noting • Regula Combi is a microprocessor-based PI controller with pulsing ON/OFF signal. • Regula Combi can control with ON/OFF and/or 0 - 10 V signal. • Regula Combi can control chilled beams in combination with VAV devices. • Regula Combi has 8 pre-defined operating programs. • Regula Combi is provided with 4 inputs and 3 outputs. • Regula Combi communicates via Modbus, EXOline or Bacnet. Order code Product Regula Regula Combi Combi Pascal Regula Combi Standard Regula Combi Pascal Including adaptor for RJ45 patch cable Example: Regula Combi Pascal lindab | we simplify construction Regula Combi 1.5 › OFF STANDBY COOL SERVICE HEAT Regula Combi REGULA CONNECT Pascal Rc LINK N = Neutral L = Load S = Signal Rc LINK RC in / out CO2 in - S1 CO2 in - S2 CO2 out - N CO2 out - L Presence in - S1 Presence in - S2 Presence out - N Presence out - L Damper in - Pos Damper out - S Damper out - N Damper out - L Heating 0-10V- S Heating 0-10V- N Heating 0-10V- L Supply Link2 - N Supply Link2 - L Supply Link1 - N Supply Link1 - L Supply in - N Supply in-24V - L LINDAB Regula Connect Pascal REGULA CONNECT Multi Rc LINK N = Neutral L = Load S = Signal Rc LINK RC in/out CO2 in - S CO2 in - S CO2 out - N CO2 out - L Presence in - S Presence in - S Presence out - N Presence out - L Damper out - S Damper out - N Damper out - L Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link - S Cooling link - S Supply link - N Supply link - L Heating link - S Cooling link - S Supply link - N Supply link - L Supply in - N Supply in 24V - L LINDAB Regula Connect Multi REGULA CONNECT Basic N = Neutral L = Load S = Signal Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_S Cooling link_S Supply link - N Supply link - L Heating link_S Cooling link_S Supply link - N Supply link - L Supply in - N Supply in - 24V - L LINDAB Regula Connect Basic Link/RC H/C/24V LINK Air flow Heat Cool Damper Actuator Actuator DAMPER HEAT COOL BUS ON CTS RS485 12 BUS B B TERA A A G0- Neu G tr 0 a - l 24V SH Shi S el H d SHIELD 1 2 Damper Control 0-10 P V OWER RJ45 SCC 3 Damper Pos 0-10V 4 RS485 A 5 RS485 B 6 7 G+ Load 24V 8 G0- Neutral 24V BUS-OK P Pos P ition S Con S trol G0- Neu G tr 0 a - l 24V G+ Loa G d + 24V S Con S trol G0- Neu G tr 0 a - l 24V G+ Loa G d + 24V S Con S trol G0- Neu G tr 0 a - l 24V G+ Loa G d + 24V H Hea H t Control C Coo C l Control G0- Neu G tr 0 a - l 24V G+ Loa G d + 24V REGUL R A egu C la O C N on T tr R ol O P L asc P a A l SCAL › OFF STANDBY COOL SERVICE HEAT Supply 24V SUP CO2 Sensor CO2 Link RJ45 RC LINK Link RJ45 RC LINK RC in/out R R J4 C 5 IN/OUT Presence P T R e E m S p . / T R E J4 M 5 P. G0- Neutral 24V 8 G+ Load 24V 7 DI2 6 +24VDC 5 DI1 4 3 Signal neutral 2 AI1 1 (11) G0- Neutral 24V 8 (10) G+ Load 24V 7 (33) DI2 6 (40) +24VDC 5 (32) DI1 4 (31) AI2 3 (24) AO2 2 (23) AO1 1 8 7 DI2 6 +24VDC 5 DI1 4 AI2 3 AO2 2 AO1 1 8 7 DI2 6 +24VDC 5 DI1 4 AI2 3 AO2 2 AO1 1 G+ G L + oad 24V G0- N G e 0 u - tral 24V S2 S2 +24VDC S1 S1 DI2 G+ G+ G L + oad 24V G0- N G e 0 u - tral 24V Regula Control Pascal Lindab reserves the right to make changes without prior notice 3 2021-04-27