Duct filter units Duct filter units ■ ■ Duct pre-filter units KPF Application Duct pre-filter units KPF are built in sup - St ply air installations before rooms, which demand higher air cleanness. KPF units RAL 9010 extend the service life of HEPA filters, F because larger dirty particles are removed EU. by pre-filters, which are built in the system before HEPA filters. Description KPF unit comprises filter of B x H x L dimensions, filter frames and bag filters of G3 to F9 class. Filter housing is made Fig. 1: Overview of sheet metal, air-tight welded according to DIN 1946 and coloured in RAL 9010. Housing is fitted with connections for 900 measuring of pressure drop. Galvanized steel sheet KPF possible (not airtight). Installation Basic frames are being fitted into the KPF units via the side opening. The procedure requires 1000 mm of free space (Fig. 1). KPF housing is fitted into the duct network via the self-locking flange. Accessories See chapter Accessories. 13 2 4 1. Housing 2. Cover plate 3. Frame 4. Filter H B Table 1: Pre-filter unit size, quantity and size of bag filters Size Weight H B x (kg) (mm) (mm) 1A 40 618 618 1B 52 618 925 1C 63 618 1232 1D 75 618 1539 1E 82 618 1846 2A 53 925 618 2B 68 925 925 2C 82 925 1232 2D 91 925 1539 2E 110 925 1846 3A 63 1232 618 3B 81 1232 925 3C 93 1232 1232 3D 110 1232 1539 3E 123 1232 1846 4 1000 592 x 592 1 1 2 2 3 1 1 2 2 3 2 2 4 4 6 Bag filter, pocket lenght 630 mm 287 x 592 – 1 – 1 – – 1 – 1 – – 2 – 2 – 87 x 287 – – – – 2 3 4 5 6 – – – – –